Applications:
SOLAR Charge controller is mainly used for solar power station ,home solar power system, solar street light control system, mobile solar power system, DC wind solar generating system.
Key Features:
1.Adopt advanced MCU microprocessor control technology.
2.12v/24v self detect to choose output voltage.
3. Advanced MPPT technology ,High converting efficiency higher than 97% for minimizing energy loss.
4.Capable of selecting different charging mode for various type of batteries
5.capable of connecting additional DC load for wide applications.
6.Three stage charge control system(bulk , absorption, and float mode)with optional temperature compensation.
7.LED indicators display charge status in real time.
8.Pulse Width Modulation(PWM)technology combined with a multi-stage charge control algorithm leads to superior charging and enhanced battery performances.
Solar Controller Advantages:
1: Solar Controller/Regulator with MPPT Technology
2: Controller/Regulator DC 12V and 24V auto detect
3: Three stage charge system for controller
4: Overcharge protection during controller work
MPPT Solar Charge Controller
SOLAR Charge controller is mainly used for solar power station ,home solar power system, solar street light control system, mobile solar power system, DC wind solar generating system.
Download Where to buy »
Technical Specification
Model | MPPT solar charger controller | ||||||
SCC1240 | SCC1260 | SCC2440 | SCC2460 | SCC4840 | |||
Rated Voltage | 12/24/48Vdc auto-detection | ||||||
Rated charge current (includeload) | 40Amp/60Amp | ||||||
Load current | 15Amp | ||||||
Input voltage range | 15-150Vdc | ||||||
Max. PV open circuit array voltage | 55Vdc | ||||||
Overload protection (DC load) | 2.0 * Inom>5s | ||||||
1.5 * Inom >20s | |||||||
1.25 * Inom temperature controlled | |||||||
Power consumption | < 10mA | ||||||
Bulk charge | 14.6Vdc (default) | 29.2Vdc (default) | 58.4Vdc (default) | ||||
Floating charge | 13.4Vdc (default) | 26.8Vdc (default) | 53.6Vdc (default) | ||||
Equalization charge | 14.0Vdc (default) | 28.0Vdc (default) | 56Vdc (default) | ||||
Over charge disconnection | 14.8Vdc | 29.6Vdc | 59.2Vdc | ||||
Over charge recovery | 14Vdc | 28Vdc | 56Vdc | ||||
Over discharge disconnection | 10.8Vdc (default) | 21.6Vdc (default) | 43.2Vdc (default) | ||||
Over discharge reconnection | 12.3Vdc | 24.6Vdc | 49.2Vdc | ||||
Temperature compensation | -13.2mV/℃ | -26.4mV/℃ | -52.8mV/℃ | ||||
Lead acid battery settings | Adjustable | ||||||
NiCad battery settings | Adjustable | ||||||
Load control mode | 1. Low Voltage Reconnect (LVR): Automatic | ||||||
2. Low Voltage Disconnect (LVD): Automatic | |||||||
3. Reconnection: warning flash before disconnect and reconnection | |||||||
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc | |||||
Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc | |||||
Ambient temperature | 0-40℃ (full load) 40℃-60℃ (de-rating) | ||||||
Altitude | Operating 5000 m, Non-Operating 16000 m | ||||||
Protection class | IP21 | ||||||
Cooling | Natural cooling | ||||||
Terminal size(fine/single wire) | #8 AWG | ||||||
Dimension(L*W*H) | 192X140X66mm |