High Frequency Online UPS ( GP Extra Smart Series)

Its cut-edge digital technology of DSP (Digital Signal Processor),can greatly improve the products performance and system reliability,and deliver a compact integration with higher power density

Power Range: 1 to 20Kva
Download Where to buy »

In Stock , , .

1.Its cut-edge digital technology of DSP (Digital Signal Processor), can greatly improve the products performance and system reliability, and deliver a compact integration with higher power density

2.Output power factor up to 0.8 – applicable to the tendency of future load evolution, and  deliver higher payload capacity;

3.Total power factor up to 90% can minimize the power loss of UPS and save utilization cost for user;

4.Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency;

5.Compliance with EMC requirements of IEC61000-4, provide your device a clean electric environment.

6.Active power factor correction (PFC) technology allows the input power fact or approaching to 1 , dramatically reducing the immunity on utility grid;

7.Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set;

8.Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user’s power supply planning;

9.Compact Design, Lower Noise;

Technical Specification

                               HP9115C  1-10KVA
Model
   1KT 1KT-XL 2KT  2KT-XL 3KT  3KT-XL  6KT  6KT-XL  10KT  10KT-XL
Capacity              
1KVA/800 W 2KVA/1600 W 3KVA/2400 W 6KVA/4800 W 10KVA/8000 W
         
Norminal voltage 220/230/240VAC Single phase 2    wire+G    
Norminal frequency 50/60 Hz      
Input  
Voltage Range      115~300VAC 120~275VAC
Frequency Range      50HZ:(46~54HZ);60HZ;(56HZ~64HZ)
Power Factor          >0.98       0.99
Output  
Voltage Precision  220/230/240X    (1±2%)VAC         
Frequency Precision    
50/60Hz ±0.05Hz
       
Power factor       0.8      0.8/0.9(Optional)
Harmonic Distortion Linear load<3%  Non-linear<6%
Overload load>110%for 47s;    
Capability load>150%for 25s; 105%<load≤125% for60s;
  load>200%for 300ms; 125%<load≤150% for30s;
    load>150%for 0.5s;
     
Current Crest Ratio 3:1          
Transfer time 0 ms(AC mode→DC mode);(AC    mode→Bypass<4ms)     
Battery  
DC Voltage   36VDC   72VDC   96VDC     192 or 240DVC
Recharge Time  
5 hours to 90% (it means standard    model which battery inside UPS)
         
Charging current  1A 4A/8A(Optional)  1A 4A/8A(Optional)  1A 4A/8A(Optional)  2A  4A  2A  4A
Panel Display  
LCD UPS status, input/output voltage and    frequency,battery voltage, capacity,load temperature,history records, adjust    Voltage, ECO mode
Communication  
Communication port Smart RS232, SNMP (Optional) , USB(Optional)
Working Environment  
Temperature     0~40°C  
Relative Humidity 0~95%    non-condensing         
Storage Temperature    -25°C~55°C      
Elevation       1500m    
Noise Level  <45dB        <50dB           <50dB 
Physical Characteristic  
    N.W  12        6.5        23  10.5       31.5    14  57  18  67.5   20
Weight(KG)  G.W  14   8   25.5         13    33.5         16.5  59  24  70  24
Dimensions:  ( W x D x H )   145x355x220   190x383x318   190x433x318   248x500x616 248x500x460   248x500x616 248x500x460

Reviews

There are no reviews yet.

Be the first to review “High Frequency Online UPS ( GP Extra Smart Series)”