– Pure sine wave inverter
– Built-in MPPT solar charge controller
– Could be built-in battery
– Protection degree:IP55
– Configurable input voltage range for home appliances and personal computers via LCD setting
– Configurable AC/Solar Charger priority via LCD setting
– Compatible to mains voltage or generator power
– Auto restart while AC is recovering
– Overload/Over temperature/short circuit protection
– Configurable battery charging current based on applications via LCD setting
Telecom Outdoor Solar Inverter
IP55 and fine dust-proof fine water-proof features for Telecom Outdoor Solar Power Inverter.
Power Range: 1 to 10Kva
Download Where to buy »
Technical Specification
MODEL | SPS3115C 1-10KVA | ||||||||
1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 1000W | |
Input wave form | Sine wave (utility or generator) | ||||||||
Normal voltage | 120VAC(option) 230VAC | 220/230/240VAC | |||||||
Low voltage re trip | 90V±4% & 184V/154V±4% | 154V | |||||||
Low voltage re engage | 100V±4% & 194V/164V±4% | 164V | |||||||
High voltage re trip | 140V±4% & 253V±4% | 273V | |||||||
High voltage re engage | 135V±4% & 243V±4% | 263V | |||||||
Normal input frequency | 50Hz/ 60Hz (auto detection) | ||||||||
Low freq trip | 47Hz for 50Hz,57Hz for 60Hz | 40Hz | |||||||
High freq trip | 55Hz for 50Hz,65Hz for 60Hz | 80Hz | |||||||
Output Wave form | (Bypass mode)same as input | ||||||||
Over-Load Protection | Circuit breaker | Yes | |||||||
Short circuit Protection | Circuit breaker | Yes | |||||||
Efficiency on line transfer mode | 95%+ | ||||||||
Line transfer time | 10ms Typical | ||||||||
Protection degree | IP55 | ||||||||
Bypass without battery connected | Yes | ||||||||
Inverter specification/output | |||||||||
Output wave form | Pure sine wave | ||||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000W | 10000W |
Output continuos power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000W | 10000W |
Power factor | 0.9-1.0 | ||||||||
Nominal Output Voltage rms | 120VAC(option) 230VAC | 230VAC | |||||||
Output Voltage regulation | +/- 10%rms | ||||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | ||||||||
Safety Certification | >88% | ||||||||
Inverter specification/input | |||||||||
Nominal input voltage | 12V/24V/48V | ||||||||
Minimum start voltage | 10V/20V/40V | ||||||||
Low battery alarm | 10.5V/21V/42V | ||||||||
Low battery trip | 10V/20V/40V | ||||||||
High voltage alarm | 16V/32V/64V | ||||||||
Charger mode spe cification | |||||||||
Output voltage | Dependent on battery type | ||||||||
Charge current | 10-85A MAX | 75A MAX | 85A MAX | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Over charge protection | 15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Solar Charge | |||||||||
MPPT Range@Operating Voltage | 15VDC~40VDC/15VDC~150VDC(Optional) 25VDC~58VDC/25VDC~150VDC(Optional) | 60VDC~110VDC 60VDC~150VDC (Optional) | |||||||
Maximum PV Array Open Circuit Voltage | 58VDC/150VDC(Optional) 110VDC/150VDC(Optional) | 110VDC/150VDC (Optional) | |||||||
Maximum Charging Current | 40A/60A | ||||||||
Maximum Effciency | >96% | ||||||||
Standby Power Consumption | 2W |